* README for FMS: Fabric Management System for Myrinet Networks   *
*                                                                 *
*******************************************************************

===================================================

Overview

The fabric management system is a collection of tools and processes used
to manage a Myrinet network.  This system relies on a database formed by
a collection of files which describe how the network is connected. Since
there is a description of how the network is supposed to look, it is possible
to report discrepancies between the observed network state and the desired
network state.  For example, without this description, a failed
switch-to-switch link could be routed around, but could not easily be
reported as missing, since there would be no way of knowing the link is
supposed to be there.

The two primary processes in the Fabric Management System are the fms (Fabric
Management Server) and fma (Fabric Management Agent).

fms runs on one machine and serves as a focal point for all management
activity on the fabric.  All errors are reported to fms, and are available
for viewing through a variety of means.

There is one fma process on each Myrinet node.  This process replaces the
previous mapper (mx_mapper or gm_mapper) and expands its functionality.  Any
errors noticed by the fma process are reported to the fms and are then
made available to system operators.

The fabric description database consists of several files in a directory,
all of which are easily human-readable and editable.  These files are read
and written by the fms process.  The current file list is:

  enclosures.csv - a list of all enclosures in the system
  linecards.csv - a list of all linecards, and where they are
  hosts.csv - a list of all the hosts in the fabric
  nics.csv - a list of all the NICs in the fabric
  links.csv - a list of all the fiber connections in the system

When error conditions are detected in the fabric, alerts are generated by
the fms process.  These can be queried on a regular basis, or the fms
can be configured to proactively report alerts through a user-defined
mechanism.


===================================================

Building FMS with MX

The FMS is integrated into the MX install package.  To build and use FMS with
MX, you need to specify "--enable-fms" on the MX configure line.  FMS will
then be installed wherever you install MX, which is /opt/mx by default.

To specify the name of the FMS server (the node on which the fms process will
be run) at configure time, use "--with-fms-server=<fms_server>".  To defer
this specification until install time, or to override it, you may install
MX with "make install FMS_SERVER=<fms_server>".  Finally, you may override
the location of the FMS server manually by editing /opt/mx/bin/mx_start_mapper.

  $ configure --enable-fms --with-fms-server=<fms_server>
  $ make install

===================================================

To build and install FMS as a standalone module:

Download FMS.
  http://www.myri.com/ftp/pub/reese/fms_src.tar.gz

 $ tar zxf fms_src.tar.gz
 $ cd fma
 $ ./configure
 $ make
 $ make install

By default, FMS assumes that MX is the low-level firmware,
and that MX is installed in the directory (/opt/mx).  (If the
GM firmware is used, the default installation directory for
GM is /opt/gm).  The FMS package is installed in the default 
directory, /opt/fms.

If you would like to specify a different FMS installation directory, 
you need to pass the --prefix option to configure. E.g., 

 $ ./configure --prefix=<install_dir>

To use GM instead of MX, or to specify an alternate install directory
for GM or MX, pass the following option(s) to configure:

 $ ./configure --with-myri-api=gm --with-myri-install-dir=<myri_install_dir>

where <myri_install_dir> is the installation directory for MX or GM.

Note: As previously mentioned, if you would like to install FMS into 
a different directory, you can pass the --prefix argument to configure
or specify the instalation directory at the "make install" step.

 $ ./configure --prefix=<install_dir>
 $ make install

or:

 $ make install prefix=<install_dir>


===================================================

Setup

Add /opt/fms/bin to your path.

FMS needs a writeable directory for keeping the fabric database,
/var/run/fms is default and preferred.

 $ mkdir -p /var/run/fms

If you need to use different directories for the FMS install dir (/opt/fms)
please set and export the environment variable FMS_INSTALL.  This will allow
all the tools to find the directory automatically.  Similarly, the default
directory of /var/run/fms can be overridden by FMS_RUN.  

Define the Myricom switch enclosures by using the "fm_switch" command:

 $ fm_switch -a <switch_name>

Where <switch_name> is the DNS name or IP address for the monitoring linecard
for each enclosure in your fabric.  Repeat for each enclosure until all are
added.  To see just a list of the enclosures currently defined, run:

 $ fm_switch

If you need to remove a switch from the list, use the "-d" option:

 $ fm_switch -d <switch_name>

===================================================

Quickstart for FMS/FMA

The FMS/FMA combination is used as a complete replacement for the mapper.

The FMS is a process which manages the fabric.  It need not have access to
the Myrinet fabric, but it must be on a machine with IP access to each compute
node and to the Myrinet switches used in the fabric.

Since FMS has a socket connection to each fma and also to each switch
enclosure, make sure the system running fms will allow enough open file
descriptors for every node in your fabric, plus every enclosure, plus another
fifty or more to be safe. (somtimes a disconnected fma may reconnect before the
OS realizes the previously used socket is now closed)

Pick a machine to run the FMS on, and install the FMS package as above.
Start the program "fms" in the background, nohup-ed, with stdout and stderr
redirected to a file.  

 $ nohup fms > <log_file> 2>&1 &

Each compute node should also have a copy of the installation directory (which
is read-only) but does not need the writeable run directory.  Start the FMA
on each compute node as:

 $ nohup fma -s <fms_server> > <log_file> 2>&1 &
 
(or the equivalent in your favorite shell)

You can restart either the fms or any or all fmas without needing to restart
the other processes, so you should really only need to start the fms once.

Use the fm_status command to see the current status of the fms.

 $ fm_status

===================================================

Appendix A - Program Usage

The following is a list of programs that work within the FMS environment.

fms - The Fabric Management Server

fma - The Fabric Management Agent

fm_switch - Manage the list of enclosures in the database.

fm_status - Show current fabric status.

fm_db2wirelist - prints out a list of switch connections in a nice format.

fm_show_alerts - Print a list of currently active alerts.

fm_ack_alert - Acknowledge an alert.

fm_walkroute - show the path through the fabric a given route will take

fm_fixup_db - May need to be run after a software upgrade which changes
	      the database format.

All tools will look for these files by default in /var/run/fms/database.
The location and name of the database directory can be overridden by
environment variables or command line arguments.

In order to easily support new hardware types produced by Myricom in the
future, the description of all the hardware products is table driven.  These
tables are included as part of the fabric management installation, and their
location can also be changed through environment variables or command line
arguments.  The default directory for the fabric management system is
/opt/fma.


Most tools have the following in common:
  Fabric Management System run directory defaults to "/var/run/fms"
  The environment variable FMS_RUN overrides this default.
  The command line option "-R" overrides both of these.

  The fabric description is kept in <fms_run>/<database_name>
  database name defaults to "database"
  The environment variable FMS_DB_NAME overrides this default.
  The command line option "-N" overrides both of these.

1. Server/Agent processes


fms -
	The fabric server, fms, is run on a server which need not be part
	of the Myrinet fabric, but must have IP connectivity to all nodes in
	the fabric and to the monitoring linecards in all the switches.  The
	fms process must have filesystem access to the database files.

	fms
	  [ -D ] - enable debug output
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

fma -
	This runs as a persistent agent on each Myrinet node. The fma node
	must have IP connectivity to the node on which the fms is running, but
	need not have access to the database files.
	The name of the fms is obtained from, in order of increasing
	precedence:
		--with-fms= from configure command
		FMS_SERVER= from "make install" command
		The environment variable "FMS_SERVER"
		The command line argument "-s"


	fma
	  [ -s <fms_server> ] - name of the node running the fms server
	  [ -d ] - run in background as daemon
	  [ -p ] - run using partitions (no standalone mode)
	  [ -x ] - fabric consists of ID-less xbars only
	  [ -i ] - fabric consists of xbars with IDs only
	  [ -l <map_level> ] - set mapping level
	  [ -D ] - enable debug output
	  [ -R <fma_run> ] - run dir
	  [ -L <logfile> ] - log filename, in <fms_run> if relative,
	  			"-" for stdout
	  [ -h ] - print usage message
	  [ -V ] - print FMS version


2. Database commands - All of these commands are run on a node which has
filesystem access to the database files.


fm_switch -
	fm_switch is used to view and manage the list of enclosures in 
	the fabric.  This command should not be used to modify the list of
	enclosures while fms is running - it is intended as a setup command
	to be used before the fms is started.

	fm_switch
	  [ -a <switch_name> ] - add <switch_name> to the database of switches
	  [ -d <switch_name> ] - remove <switch_name> from the
	                         database of switches
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name
	  [ -h ] - print usage message
	  [ -V ] - print FMS version


fm_db2wirelist -
	This reads the database of connections and prints out a list of the
	contents of each switch's slots and where everything is connected.
	Running and reviewing this as a first step after creating the
	database is a good way to notice links that are out.
	This is run on a node which has filesystem access to the database files.
	Since this program does not modify the database, it can be run at any
	time.

	fm_db2wirelist
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

fm_settings -
	This is used to view and change settings for the FMS.  This should
	be run to change parameters while the FMS is not running, and the
	FMS will pick up the new values when it restarts.  These parameters
	are saves in the database table "fms_settings".

	fm_settings
	  [ -p <paramater> <value> ] - set <parameter> to <value>
	  [ -l ] - list all parameters and their values
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

fm_walkroute -
	This is used to see the exact path a packet takes through the network
	given a starting host and a sequence of route bytes.
	This is run on a node which has filesystem access to the database files.
	Since this program does not modify the database, it can be run at any
	time.

	fm_walkroute
	  [ -f <hostname> ]	- the host from which to start
	  [ -n <nic_id> ]	- which NIC to use
	  [ -p <port> ]		- which port on the NIC to use
	  [ -g ]		- give extra-gory details about internal links
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

	Example usage:
	  $ fm_walkroute -f host1 -- bd bf 90 91
	  Walking route: -3 -1 16 17 from host host1 nic 0
	  host host1 nic 0, rail 0 - switch1, slot 15, port 9
	  switch1, slot 14, port 6 - switch2, slot 9, port 28
	  switch2, slot 6, port 22 - host host37, nic 0, rail 0

fm_fixup_db -
	May need to be run after a software upgrade which changes the
	database format.  The database is read and re-written if any changes
	are needed.  If no changes are needed, the database is left untouched.

	fm_settings
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name
	  [ -h ] - print usage message
	  [ -V ] - print FMS version


3. FMS Client Commands - These programs make IP queries to the fms server
and need only be run on nodes which have IP access to the fms.  The fms must
be running for these commands to work.

fm_status -
	Print a summary of fms status.

	fm_status
	  [ -s <fms_server> ]	- address of node with fms process
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

	Example:
	  $ fm_status
	  FMS Fabric status

	  32      hosts known
	  31      FMAs found
	  1       un-ACKed alerts
	  Mapping is complete, last map generated by fog20
	  Database is complete

	"hosts known" is the count of all hosts in the database
	"FMAs found" is the number of FMAs currently in contact with fms
	"un-ACKed alerts" is a count of alerts not yet ACKed (see
	  fm_show_alerts)
	"Mapping is complete/in progress" tells whether mapping
	  activity is occurring at this moment.
	"Database is/is not complete" tells whether the resolution of xbars
	  found by mapping into specific linecards is complete yet or not.

fm_show_alerts -
	Print a list of active alerts.  By default, this prints only
	alerts which have not been ACKed and are not relics. (See appendix
	on "Alerts" below).

	Each alert has a unique index which can be passed to fm_ack_alert
	to acknowledge the alert.

	fm_show_alerts
	  [ -a ]		- show ACKed alerts also (marked with [A])
	  [ -r ]		- show relic alerts also (marked with [R])
	  [ -s <fms_server> ]	- address of node with fms process
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

fm_ack_alert -
	Acknowledge an alert.  This marks an alert as ACKed, possibly causing
	its deletion.  (See appendix on "Alerts" below).

	fm_ack_alert
	  [ -i <id> ]		- ACK alert with ID <id>
	  [ -s <fms_server> ]	- address of node with fms process
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

fm_maint -
        Place a linecard into or out of maintenance mode.  While in maintenance
	mode, the xbars on a linecard will be treated as though they do not
	exist.

	fm_maint
	  [ -h ]		- print this help message
	  -e <enclosure>	- switch enclosure name
	  -l <slot_no>		- slot number of linecard to maintain
	  [ -p <slot_no> ]	- port number to maintain
	  -m { up | down }	- set the state to up or down
	  [ -s <fms_server> ]	- address of node with fms process
	  [ -h ] - print usage message
	  [ -V ] - print FMS version

	This is useful for working on a linecard while jobs are in progress
	since no remapping is caused.  If optional port number is not specified,
	then all ports on the linecard are affected.


Appendix B - Alerts

Alerts are created when certain exceptional events occur and are reported
to the fms.  Alerts persist within the fms until they are cleared.  Clearing
usually requires the alert to be acknowledged (ACKed) and for the condition
which caused the alert to have cleared.

Once the alert has been acknowledged, it is marked as "ACKed".  Once the
condition that caused the alert has cleared, we mark it as a "relic."
Most alerts are deleted only after they have been both relic-ed and ACKed.

The following is a list of all alerts and their meanings.  The "flags" line
for each alert type may contain "NEEDS_ACK" or "ACK_ONLY" or both.
If NEED_ACK is present, once the alert becomes a relic, it still needs an
ACK before it is deleted entirely.  If NEED_ACK is not present, the alert
is deleted as soon as it becomes a relic.
If ACK_ONLY is specified, the event is deleted as soon as it is ACKed.  Without
this flag, the alert will persist until becoming a relic, even after it has
been ACKed.


HOST_NO_INITIAL_FMA
Description: No FMA connection has been established since FMS was started
Initiated_by: timeout waiting for FMA connection
Cancelled_by: attachment to FMA
Flags:
struct {
  lf_string_t hostname;
}
Format: "Have never gotten FMA contact from %s"
Args: hostname

HOST_LOST_FMA
Description: Connectivity was lost to the FMA on a host
Initiated_by: A connection to a running FMA was lost
Cancelled_by: re-attachment to FMA
Flags: NEED_ACK
struct {
  lf_string_t hostname;
}
Format: "Lost FMA contact from %s"
Args: hostname

HOST_LINK_DOWN
Description: A myrinet link between a host and switch is disconnected
Initiated_by: inability to pass traffic through a link
Cancelled_by: resumption of traffic through the link or removal of the link
Flags: NEED_ACK
struct {
  lf_string_t hostname;
  uint16_t nic;
  uint16_t nic_interface;
  lf_string_t enclosure;
  uint16_t slot;
  uint16_t port;
  uint16_t subport;
}
Format: "Link from %s, nic %d:p%d to %s, slot %d, port %d:%d is down"
Args: hostname nic nic_interface enclosure slot port subport

HOST_SRAM_PARITY_ERROR
Description: A NIC on a host has experienced an SRAM parity error
Initiated_by: SRAM parity error reported by NIC
Cancelled_by: ACK
Flags: ACK_ONLY NEED_ACK
struct {
  lf_string_t hostname;
  uint32_t nic_id;
  lf_string_t serial_no;
}
Format: "%s, NIC %d (serial_no=%s) got an SRAM Parity Error"
Args: hostname nic_id serial_no

HOST_FIRMWARE_DIED
Description: A NIC on a host has stopped responding
Initiated_by: NIC error reported by Myri interface
Cancelled_by: ACK
Flags: ACK_ONLY NEED_ACK
struct {
  lf_string_t hostname;
  uint32_t nic_id;
  lf_string_t serial_no;
}
Format: "%s, NIC %d (serial_no=%s), is not responding"
Args: hostname nic_id serial_no

SWITCH_XBARPORT_DISABLED
Description: An xbar port on an enclosure has been manually disabled
Initiated_by: xbar port is seen to be disabled
Cancelled_by: xbar port is no longer disabled
Flags: 
struct {
  lf_string_t enclosure;
  uint32_t slot;
  uint32_t xbar;
  uint32_t port;
}
Format: "Enclosure %s, slot %d, xbar %d, port %d disabled"
Args:  enclosure slot xbar port

SWITCH_EXT_LINK_DOWN
Description: An external myrinet link between two switches is disconnected
Initiated_by: inability to pass traffic through a link
Cancelled_by: resumption of traffic through the link or removal of the link
Flags: NEED_ACK
struct {
  lf_string_t enclosure1;
  uint16_t slot1;
  uint16_t port1;
  uint16_t subport1;
  lf_string_t enclosure2;
  uint16_t slot2;
  uint16_t port2;
  uint16_t subport2;
}
Format: "Link from %s, slot %d, port %d:%d to %s, slot %d, port %d:%d is down"
Args: enclosure1 slot1 port1 subport1 enclosure2 slot2 port2 subport2

SWITCH_INT_LINK_DOWN
Description: Am internal myrinet link between two xbars is disconnected
Initiated_by: inability to pass traffic through a link
Cancelled_by: resumption of traffic through the link or removal of the link
Flags: NEED_ACK
struct {
  lf_string_t enclosure;
  uint16_t slot1;
  uint16_t xbar1;
  uint16_t port1;
  uint16_t slot2;
  uint16_t xbar2;
  uint16_t port2;
}
Format: "Internal link from %s, slot %d, xbar %d, port %d to slot %d, xbar %d, port %d is down"
Args: enclosure slot1 xbar1 port1 slot2 xbar2 port2

SWITCH_XBARPORT_DOWN
Description: An xbar port on an enclosure is down
Initiated_by: xbar port is seen to be down
Cancelled_by: xbar port is no longer down
Flags:  NEED_ACK
struct {
  lf_string_t enclosure;
  uint32_t slot;
  uint32_t xbar;
  uint32_t port;
}
Format: "Enclosure %s, slot %d, xbar %d, port %d is down"
Args:  enclosure slot xbar port

SWITCH_XBARPORT_UPDOWN_COUNT
Description: An xbar port has toggled state too frequently
Initiated_by: xbar port changes to "down" too many times w/in sample period
Cancelled_by: ACKed by user
Flags:  NEED_ACK
struct {
  lf_string_t enclosure;
  uint32_t slot;
  uint32_t xbar;
  uint32_t port;
  uint32_t updown_count;
  uint32_t seconds;
}
Format: "Enclosure %s, slot %d, xbar %d, port %d: %d state changes in %d seconds, port disabled"
Args:  enclosure slot xbar port updown_count seconds

SWITCH_XBARPORT_BADCRC_COUNT
Description: An xbar port has a badcrc count that is too high.
Initiated_by: An xbar accumulates too many badcrcs over the sample period.
Cancelled_by: ACKed by user
Flags:  NEED_ACK ACK_ONLY
struct {
  lf_string_t enclosure;
  uint32_t slot;
  uint32_t xbar;
  uint32_t port;
  uint32_t badcrc_count;
  uint32_t seconds;
}
Format: "Enclosure %s, slot %d, xbar %d, port %d: %d Bad CRC packets in %d seconds."
Args:  enclosure slot xbar port badcrc_count seconds

SWITCH_EXT_LINK_BADCRC_COUNT
Description: An link has a badcrc count that is too high.
Initiated_by: An xbar port accumulates too many badcrcs over the sample period.
Cancelled_by: ACKed by user
Flags:  NEED_ACK ACK_ONLY
struct {
  lf_string_t enclosure1;
  uint16_t slot1;
  uint16_t port1;
  uint16_t subport1;
  lf_string_t enclosure2;
  uint16_t slot2;
  uint16_t port2;
  uint16_t subport2;
  uint32_t badcrc_count;
  uint32_t seconds;
  lf_string_t extra_text;
}
Format: "Link from %s, slot %d, port %d:%d to %s, slot %d, port %d:%d: %d Bad CRC packets in %d seconds%s"
Args: enclosure1 slot1 port1 subport1 enclosure2 slot2 port2 subport2 badcrc_count seconds extra_text

SWITCH_INT_LINK_BADCRC_COUNT
Description: An internal link has a badcrc count that is too high.
Initiated_by: An xbar port accumulates too many badcrcs over the sample period.
Cancelled_by: ACKed by user
Flags:  NEED_ACK ACK_ONLY
struct {
  lf_string_t enclosure;
  uint16_t slot1;
  uint16_t xbar1;
  uint16_t port1;
  uint16_t slot2;
  uint16_t xbar2;
  uint16_t port2;
  uint32_t badcrc_count;
  uint32_t seconds;
  lf_string_t extra_text;
}
Format: "Internal link from %s, slot %d, xbar %d, port %d to slot %d, xbar %d, port %d: %d Bad CRC packets in %d seconds%s"
Args: enclosure slot1 xbar1 port1 slot2 xbar2 port2 badcrc_count seconds extra_text

SWITCH_HOST_LINK_BADCRC_COUNT
Description: A host link has a badcrc count that is too high.
Initiated_by: An xbar port accumulates too many badcrcs over the sample period.
Cancelled_by: ACKed by user
Flags:  NEED_ACK ACK_ONLY
struct {
  lf_string_t hostname;
  uint16_t nic;
  uint16_t nic_interface;
  lf_string_t enclosure;
  uint16_t slot;
  uint16_t port;
  uint16_t subport;
  uint32_t badcrc_count;
  uint32_t seconds;
}
Format: "Link from %s, nic %d:p%d to %s, slot %d, port %d:%d: %d Bad CRC packets in %d seconds"
Args: hostname nic nic_interface enclosure slot port subport badcrc_count seconds

SWITCH_XCVR_DISABLED
Description: A transceiver port on an enclosure has been manually disabled
Initiated_by: transceiver port is seen to be disabled
Cancelled_by: transceiver port is no longer disabled
Flags:
struct {
  lf_string_t enclosure;
  uint32_t slot;
  uint32_t port;
}
Format: "Enclosure %s, slot %d, port %d disabled"
Args:  enclosure slot port

SWITCH_XCVR_SIGNAL_LOST
Description: A transceiver port on an enclosure has lost signal
Initiated_by: transceiver signal_lost noted
Cancelled_by: transceiver signal_lost condition clears
Flags: NEED_ACK
struct {
  lf_string_t enclosure;
  uint32_t slot;
  uint32_t port;
}
Format: "Enclosure %s, slot %d, transceiver port %d lost signal"
Args:  enclosure slot port

SWITCH_LINECARD_HOT
Description: A linecard is too hot
Initiated_by: observed temp is over threshold
Cancelled_by: all temps are less than threshold - hysteresis value
Flags: NEED_ACK
struct {
  lf_string_t enclosure;
  uint32_t slot;
}
Format: "Enclosure %s, slot %d is running hot"
Args:  enclosure slot

SWITCH_LINECARD_OVERTEMP
Description: A linecard is so hot it shut down
Initiated_by: overtemp count increased
Cancelled_by: ACK only
Flags: NEED_ACK ACK_ONLY
struct {
  lf_string_t enclosure;
  uint32_t slot;
}
Format: "Enclosure %s, slot %d has experienced an overtemp shutdown"
Args:  enclosure slot

SWITCH_CANNOT_READ
Description: Cannot read data from the monitoring line card
Initiated_by: inability to contact switch
Cancelled_by: contact restored to switch
Flags: NEED_ACK
struct {
  lf_string_t enclosure;
}
Format: "Cannot contact monitoring linecard on %s"
Args:  enclosure


Appendix C - Database File Formats

Every DB file starts with 2 rows of column headers.  The first row defines
the data type of each column, and the second row defines the name of each
column.

enclosures.csv - defines the name and type of each enclosure
  string,string
  name,product_id
  clos0,M3-E128
  clos1,M3-E128
  spine0,M3-E128

linecards.csv - defines the type and location of every linecard
  string,integer,string,string
  enclosure_name,enclosure_slot,product_id,serial_no
  clos0,1,M3-SW16-8F,4936
  clos0,9,M3-SW16-8F,26848
  clos1,1,M3-SW16-8F,4937
  spine0,1,M3-SPINE-8F,22781

hosts.csv - names every host
  string,string
  hostname,sw_version
  host0000,GM
  host0001,GM
  host0002,GM
  host0003,GM

nics.csv - type and location of every NIC
  string,integer,MAC,integer,integer,string,string
  hostname,host_nic_id,mac_addr,ports,subports,serial_no,product_id
  host0000,0,00:60:dd:49:97:01,1,1,26848,M3F-PCIXD-2
  host0001,0,00:60:dd:49:97:02,1,1,31875,M3F-PCIXD-2
  host0002,0,00:60:dd:49:97:03,1,1,6878,M3F-PCIXD-2

links.csv - every link in the system
  string,integer,integer,integer,string,integer,integer,integer
  name_1,slot_1,port_1,subport_1,name_2,slot_2,port_2,subport_2
  host0000,0,0,0,clos0,9,8,0
  host0001,0,0,0,clos0,9,9,0
  host0002,0,0,0,clos0,9,10,0
  clos0,1,8,0,spine0,1,0,0
  clos1,1,8,0,spine0,1,1,0


Appendix D - FMS Settings

The following parameters may be set using fm_settings to control the
behavior of the Fabric Management System.

low_freq_monitor_interval         120 seconds [default]
  This specifies the "low frequency" interval for summing certain counts
  and comparing them to thresholds.  For example, if too many badcrc counts
  are seen on a switch during this period, an alert will be raised.

lf_badcrc_threshold               5 badcrcs [default]
  Maximum number of badcrcs allowed on a link during the low-frequency
  interval before an alert is generated.

lf_fatal_badcrc_threshold         100 badcrcs [default]
  If more than this many badcrcs are seen on a link during the low-frequency
  interval, an alert is raised and the link may be disabled to traffic.

very_low_freq_monitor_interval    1800 seconds [default]
  This specifies the "very low frequency" interval for summing certain counts
  and comparing them to thresholds.

vlf_portflip_threshold            10 transitions [default]
  If a port goes up and down more than this many times during the very-low-
  frequency interval, an alert is raised.

switch_query_interval             30 seconds [default]
  Interval between querying the monitoring linecards on the switch
  enclosures.

link_verify_interval              30 seconds [default]
  Interval for the FMAs to veryify each link in the fabric.

link_verify_timeout               100 ms [default]
  Time allowed for a response to a link verification packet to return before
  trying again or marking the link down.

link_verify_retries               3 retries [default]
  Number of times to retry probing a link before it is marked down.

linecard_overtemp_threshold_0     48 degrees C [default]
linecard_overtemp_threshold_1     48 degrees C [default]
  Temperature thresholds for the tempertures measured on linecards.  If the
  temperature is seen to be above this value, an alert is raised.
  
linecard_overtemp_hysteresis_0    3 degrees C [default]
linecard_overtemp_hysteresis_1    3 degrees C [default]
  Amount below the overtemp the temperature must fall before an overtemp
  alert if relic-ed.

Appendix E - Legacy tools

These are not in general use any longer, but still exist.

fm_create_db -
	This takes a map file generated by gm_mapper and a list of
	switch names and generates the database files for use by other
	tools.  This is much the same as the existing wirelist tool.

	The resulting fabric database will contain only the hosts and links
	included in the specified map file.  Any links or hosts not present
	in the map file can easily be added manually afterwards.

	fm_create_db
	  -s <switch_list>		- list of switch names
	  -l <low_cnt>			- low "invalid-route" threshold
	  -m <map_file>			- gm_mapper map file
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name

	switch_list is a file with one switch name or IP address per line.
	This should be the complete list of switches providing connectivity
	for the hosts in the map file, and each must have a monitoring
	line card installed.

	map_file is a map file generated by gm_mapper.  For best results,
	it should be as complete as possible, with no links out.


fm_watch_switches -
	fm_watch_switches periodically reads the information from all
	switch enclosures specified in the fabric database and reports
	information which may require attention.

	It monitors certain counts for each port, and reports any whose
	delta since the last iteration exceeds a specified threshold.
	Variables monitored for each crossbar port are:
	  badcrcs - the number of badcrcs seen
	  rx_timeouts - the number of receive timeouts
	  tx_timeouts - the number of transmit timeouts

	fm_watch_switches can also be used to report which ports,
	either transceiver or crossbar ports, have been manually disabled.

	fm_watch_switches
	  [ -a ]		- show absolute values used to compute deltas
	  [ -t <threshold> ] 	- reporting threshold, default 5
	  [ -i <interval> ]	- polling interval in seconds, default 30
	  [ -g ] 		- watch goodcrc counts
	  [ -r ]		- Show RX Timeout counts
	  [ -d ]		- report disabled links
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name
	  [ -V ] - print FMS version

	Usage:
	fm_watch_switches is a good diagnostic test to run when looking 
	for links with high crc counts, especially while jobs are running 
	since load will be high. fm_watch_switches does not interact with 
	the fabric at all, so it is completely non-intrusive. If any links 
	start showing excessively high badcrc rates, diagnostics should be
	performed (replace cable, etc.) 

fm_linktest -
	fm_linktest is used to look for failed or marginal interswitch
	links.  It takes as input the fabric description and tests
	every interswitch link in the fabric individually.  This includes
	links between crossbars inside a switch.  

	Marginal or failed links are identified and reported.

	fm_linktest
	  [ -n <nic_id> ]	- the which NIC to use, default 0
	  [ -i <host_ifc> ]	- which NIC interface to use, default all
	  [ -l <kbytes> ]	- length of test packets in KB, default 4
	  [ -R <fms_run> ] [ -N <fms_db_name> ] - run dir and DB name

	-i specifies which interface to use on multi-interface NICs like
	   E cards.  This option is not normally used since all interfaces
	   are tested by default.

	Usage:
	fm_linktest can be run periodically as a health check of the fabric. 

	Example output:
	The link from clos1 / slot 2 / port 5 to spine3 / slot 6 / port 13 
	seems completely down, no traffic passes.

	Or 
	The link from clos1 / slot 2 / port 5 to spine3 / slot 6 / port 13 
	seems marginal, 50 / 80 packets were successfully transmitted.

	Or 
	The internal link from clos1 / slot 9 / xbar 3 / port 17 to clos1 / 
	slot 0 / xbar 0 / slot 1 is XXX.

	This latter message indicates that there is definitely a card or 
	enclosure problem. The first 2 messages indicate that cable diagnostics 	need to be run. 

	fm_linktest can be run anytime to look for dead links, but when run 
	on an active network, false positives may appear on marginal links. 
	The option -l 4 (just a few packets) is good for looking for dead 
	links and can be performed anytime. The option -l 4000 is primarily 
	used for finding marginal links and should be run on an
	unloaded network. 